Stereophile

MEASUREMENTS

I used DRA Labs’ MLSSA system and a calibrated DPA 4006 microphone to measure the KEF LS50’s frequency response in the farfield, and an Earthworks QTC-40 for the nearfield and spatially averaged room responses. My estimate of the LS50 Meta’s voltage sensitivity was 84.5dB(B)/2.83V/m, which is the same as that of the original and within experimental error of the specified 85dB.

The solid trace in fig.1 shows how the Meta’s impedance magnitude varies with frequency. Below 200Hz, it is almost identical to that of the paper to calculate the “equivalent peak dissipation resistance” (EPDR). The LS50 Meta has minimum EPDRs of 1.66 ohms between 135Hz and 140Hz and 1.7 ohms between 660Hz and 725Hz, both regions where music can have high energy. The partnering amplifier needs to be comfortable driving 4 ohms.

You’re reading a preview, subscribe to read more.

More from Stereophile

Stereophile5 min read
Measurements
I measured a different sample of the Octave Audio V 70 Class A than that auditioned by RS. Mine had the serial number 22018130 and was not fitted with the optional phono module. As RS primarily used the balanced line input and KT120 output tubes with
Stereophile3 min read
Measurements
I performed a complete set of measurements on one of the Linn Klimax Solo 800s (serial number 1593390) with my Audio Precision SYS2722 system.1 I preconditioned the Solo 800 by following the CEA’s recommendation of running it at one-eighth the specif
Stereophile4 min read
Letters
When my Stereophile reaches my doorstep, the first thing I turn to is Herb Reichert’s reviews. I don’t care what he’s reviewing; I love how he writes about it. In April’s edition, he shared his thoughts on an unexpected emotional response to Brice Ma

Related